Adept Scientific - Suomi Finland
Maailman johtava ohjelmisto tutkimukselle,tieteelle ja teknologialle
flag arrow
clearclear
Flag

 Adept Store | register Join My Adept | Flags  
Adept Scientific | Mannerheimintie 12 B, 5th floor | FIN-00100 Helsinki | Finland | Tel: 0 800 77 32 50  
UKusdedksvnofi
Koti
Tuotteet
Kurssit
Services
 Osta nyt!
Lataukset
Koulutus
Tuki
Minun Adept
Kansainvälinen |  Meistä |  Blog |  Ota meihin yhteyttä |  Lehdistö |  Työ ja Ura


Etene

• Ask us a question
• Buy Quality Monitor Now
• View Quality Monitor Pricing
• Sign up for a Webinar
• Download a Brochure
• Request a Brochure
• Download a Product Tour
• Meet Our Team

Opi enemmän

NWA Product Overview

Quality Monitor Home
Quality Monitor Supervisor
A Cost Effective Solution
Easy to Set Up
Easy to Use
Easy to Integrate
Easy to Interface
Design & Specifications
Quality Monitor
Payback Calculation


System Requirements
Rave Reviews

Quality Analyst

Viimeisin tieto

What's New in NWA
Quality Monitor 2.4

21CFR Part 11 Compliance

Huolto & Tuki

Patches & Downloads
Search the Knowledge Base
Technical Support request

NWA Quality Analyst

Design and Specifications

Graphical Designer
Click to view enlargement
Visual tool for creating full screen user interface designs.

Device Configuration
Click to view enlargement
Measurement device configuration and communications diagnostics

Help Editor
Click to view enlargement
Create context-sensitive help and SOPs.

NWA Quality Monitor provides SQC charts for all types of measurements—whether variable or attribute—in one package. The software offers the same chart-generating capabilities as our award-winning NWA Quality Analyst, producing all standard SQC/SPC charts and reports.

Variable Control Charts

  • X-bar
  • Range
  • Standard Deviation
  • Individual Measurements
  • Moving Average
  • Median
  • Median/Individual Measurements
  • Cumulative Sum (CUSUM)
  • Exponentially Weighted Moving Average (EWMA)

Attribute Control Charts

  • Percent Defective (p)
  • Number Defective (np)
  • Defects (c)
  • Defects per Unit (u)

Short Run Analysis (for all charts)

Pareto Analysis

Process Capability Analysis

Select one of eight distribution types:

  • Normal
  • Skewness and Kurtosis Adjusted (Johnson)
  • Two Parameter Log normal
  • Three Parameter Log normal
  • Truncated Normal
  • Folded Normal
  • Weibull
  • Rayleigh

User Interface Components

User Interface can be composed of any number and combination of components

  • Input Box
    • Key entry
    • Measurement device input
  • Display Box
    • Calculations
    • Informational data
  • Tabulate Box - simplifies defect category entry
  • Combo Box - drop-down selection list
  • Input Prompt - specific to each Input Box
  • Label Text - full font and colour control
  • Picture - supports BMP, GIF, JPG, and PNG formats
  • Command Bar - dockable groups of command buttons
  • Pop-up Menu - cascading groups of command buttons
  • Action Button - individual command button
  • Alarm Indicators - alarms linked to each input and display box
  • Alarm List - displays current alarms

Data Input Options

Input source and management features

  • Source
    • Keyboard entry
    • Read from measurement device
    • Read from barcode
    • Calculation result from defined formula
    • Constant value
    • Incrementing or sequence count
    • Default to previous value
    • System date - system clock
    • System time - system clock
  • Upper and Lower Bound limits
  • Allow/Prevent modification of existing data
  • Input Mask for key, device, and calculation input
  • Field-specific prompt text
  • Field-specific help reference

User Commands

Command Bar, Pop-up Menu, and Action Button options

  • Command bars dock to any margin
  • Pop-up menus cascade to 10 levels
  • Button text includes full font and color control
  • Button definition includes short-cut (function) keys
  • Command Actions
    • Display Chart - display SPC charts
    • Print Chart - print SPC charts
    • Help - display field-specific help
    • Alarms - display alarm lists
    • Run - start Quality Analyst automation script
    • Send - send pre-defined commands to devices
    • Launch - start other Windows applications
    • Archive - manually start data archive

Help System

Complete SOP support on the plant floor

  • Context sensitive help for each input field
  • Full font and colour control
  • Embedded graphics and pictures
  • Includes built-in Help file editor
  • Reads RTF file format from word processors and editors

Alarm System

Visual and audible alarming on specifications and SPC limits

  • Alarm Types
    • Specifications
    • SPC Limits - control and warning
    • Fixed Limits
  • Alarm Indicators
    • Separate indicators for each alarm type
    • Specific to each Input and Display field
  • Alarm Lists
    • Fully definable text for each alarm type
    • Pop-up or continuous display
    • Includes complete alarm history for each data record
  • Alarm actions
    • Add message to alarm list
    • System beep
    • Assign text comment to data field

Device Interface

Real-time data collection from measurement devices

  • Interfaces through standard RS-232 (serial) ports
  • Simple point-and-click device definition
  • Interfaces with common measurement devices
    • Scales
    • Gages
    • Multiplexers
  • Special Purpose
  • Includes extensive library of predefined devices
  • Device configuration and troubleshooting tool
    • Troubleshoot communications problems
    • Test input devices

Data Storage & Connectivity

  • Uses NWA Quality Analyst Data Sets
  • Allows up to 200 characteristics per Data Set
  • Includes any combination of variable, attribute, or descriptive data
  • Automatically writes to ODBC-compliant databases; e.g., SQL Server, Oracle, MS Access, etc.

Configuration and Licensing

  • NWA Quality Analyst required for Data Set definition and SPC chart configuration
  • NWA Quality Monitor Designer (screen design, device configuration, help) to configure plant-floor workstations
  • NWA Quality Monitor Runtime installs on each plant-floor workstation

System Requirements

  • Windows 95, 98, 2000, Me, NT4
  • Any PC-based LAN (NT, Novell, etc.)

Recommended minimum systems:

  • Quality Monitor Designer:
    266 MHz Pentium,
    32 MB RAM
  • Quality Monitor Plant-floor Workstations:
    120 MHz Pentium,
    16 MB RAM
    Note:
    Existing 486 and slower Pentium systems may be used for plant-floor workstations, depending on size and complexity of data input screens.


Ostovalmis

NWA Quality Analyst
Add to shopping basket
€ 1.205,00
NWA Quality Monitor Designer
Add to shopping basket
€ 3.510,00
NWA Quality Monitor v2.3 - Workstation single user licence
Add to shopping basket
€ 870,00

Featured Downloads

NWA Quality Monitor Product Tour
NWA Quality Monitor Patches and Updates
NWA Quality Monitor Configuration Manual

Product Reviews

Over the three shifts we are saving about £5,000 a year and the most recent release of NWA Quality Monitor is reducing the labour time even further.
Keith John, BAS Components
adept

Top of the Page

Our Privacy and Terms and Conditions Statement
All Trademarks Recognised. Copyright © 2008, Adept Scientific.
Site designed and maintained by Adeptise

Adept Scientific | Mannerheimintie 12 B, 5th floor | FIN-00100 Helsinki | Finland | Tel: 0 800 77 32 50