Adept Scientific - Suomi Finland
Maailman johtava ohjelmisto tutkimukselle,tieteelle ja teknologialle
flag arrow
clearclear
Flag

 Adept Store | register Join My Adept | Flags  
Adept Scientific | Mannerheimintie 12 B, 5th floor | FIN-00100 Helsinki | Finland | Tel: 0 800 77 32 50  
UKusdedksvnofi
Koti
Tuotteet
Kurssit
Services
 Osta nyt!
Lataukset
Koulutus
Tuki
Minun Adept
Kansainvälinen |  Meistä |  Blog |  Ota meihin yhteyttä |  Lehdistö |  Työ ja Ura


Etene

• Ask us a question
• Meet Our Team
• Read our RSS Feeds

Opi enemmän

Tecplot Focus
Tecplot Focus Features
Tecplot Focus FAQs
Tecplot Focus
System Requirements


Tecplot 360 for CFD

Tecplot Rave Reviews
A-Z of Visualisation
Software Basics
Quick Tutorials

Viimeisin tieto

Showcase
  • Image Gallery
  • Case Studies
  • Plot of the Month
  • Tecplot Tips

Industry Partners
Online Training

Huolto & Tuki

Patches & Downloads
Search the Knowledge Base
Technical Support request

Tecplot

New Features 4.0
Feature List
CFD Solutions
Functions & Integration Types
Sys. Requirements
CFD Analyser 4.0 - Features

CFD Analyzer now takes advantage of the sophisticated new functionality in Tecplot 10.

New features include support for auxillary and cell-centered data, the ability to create and use shared variables, and a new data journaling capability.

01. Integrated Into Tecplot's Menu Bar 06. Data Journaling
02. Cell-Centered Data Option 07. Improved Calculation Performance
03. Auxiliary Data 08. Blanking for Feature Extraction
04. New Particle Mass Options 09. Continuous Gradients Across Zone Boundaries
05. Create and Use Shared Variables 10. Tecplot 10 Element Type

1. Integrated Into Tecplot's Menu Bar
CFD Analyzer's main dialog has been eliminated and replaced with a CFD Analyzer pull-down menu in Tecplot's menu bar. This eliminates the blocked view caused by the old dialog.



2. Capability for Cell-Centered Data
All CFD Analyzer features have been modified to accommodate cell-centered variables. Additionally, the Calculate and Turbulence dialogs have a dropdown to allow the user to specify the location of new variables.



3. Auxiliary Data
CFD Analyzer will recognize and use zone and data set auxiliary data to store all dialog settings. It will not mark data sets as "changed," so the user will not be forced to save a new data file when saving a layout. This has additional important implications:
  • Data loaders like FLUENT and Plot3D can pass CFD Analyzer dialog settings (such as fluid properties or the identification of vector variables). CFD Analyzer uses these values to pre-set many of the dialog inputs.
  • CFD Analyzer dialog settings are maintained individually for each data set. Users can copy and paste settings between data sets.


4. New Options for Particles with Mass
  • Gravity and buoyancy. The Particle Mass Options dialog has additional controls to specify the magnitude and axis direction of gravity. The effect of buoyancy is activated when detailed mass options are specified.
  • Option for zero particle initial velocity. The user has the option of starting massed particles at zero initial velocity or at the local flow velocity for each release point.
  5. Create and Use Shared Variables
This feature is useful for (but is not restricted to) grid quality calculations for unsteady solutions where the grid variables are shared for all zones. The created grid quality variables in this case will also be shared.



6. Data Journaling
CFD Analyzer journals all data alterations to avoid changing the input data file when layouts are created. Journaled data-altering operations can be undone by selecting Undo from Tecplot's Edit menu.



7. Improved Calculation Performance
CFD Analyzer operations that frequently access the data set, such as calculating new variables, have been accelerated.


8. Blanking for Feature Extraction
For ordered zones only, separation/attachment lines and vortex cores can optionally not be calculated in blanked regions. This option is available through a new toggle in the Extract Flow Features dialog.



9. Continuous Gradients Across Zone
      Boundaries

The user can enforce the calculation of continuous gradients when the "Connect Adjacent Zones" toggle is set in the Geometry and Boundaries dialog. Any zones whose boundary nodes overlap will have continuous (or nearly continuous) gradients across those zone boundaries as well.




10. New Tecplot 10 element type
The new FE line segment is now supported in CFD Analyzer.



Ostovalmis

For more pricing information:
Visit our webstore, call us on +358 (0)9 25 16 63 33 or email us at info@fi.adeptnordic.com

Product Reviews

"Tecplot software has provided an incredible boost to our productivity in terms of our research output and the insights we are able to obtain."
Rajat Mittal, George Washington University
adept

Top of the Page

Popular Links: ChemDraw | ChemOffice | Data Acquisition | Data Analysis | Easy-PC | EndNote | Maple | MapleSim | Mathcad | MathType | Quality Analyst | Reference Manager | VisSim

Our Privacy and Terms and Conditions Statement
All Trademarks Recognised. Copyright © 2008, Adept Scientific.
Site designed and maintained by Adeptise

Adept Scientific | Mannerheimintie 12 B, 5th floor | FIN-00100 Helsinki | Finland | Tel: 0 800 77 32 50